Long Slit MOS Observations
NIRSpec long slit MOS observations can be specified directly in the APT MOS observation template. This method is primarily used for MOS observations of extended fixed targets, or moving targets for which MSATA is not needed or not possible. When observing with the long slit, neither the MSA Planning Tool (MPT) nor the MSA Configuration Editor is used. Two pre-defined long slit MSA Configurations can be selected in the Configurations/Pointings table of the observation template. Note that if the user does not provide an angle special requirement, STScI will assign one.
On this page
Creating a long slit MOS observation
Words in bold are GUI menus/
panels or data software packages;
bold italics are buttons in GUI
tools or package parameters.
Several TA methods are provided within the NIRSpec MOS observation APT template for use with the pre-defined long slits or a custom designed MSA Configuration. For example, the JWST NIRSpec wide aperture target acquisition (WATA) observing sequence uses the S1600A1 wide aperture to perform target acquisition of moving science targets, stationary science targets, and stationary offset targets fainter than AB ~ 12.4 mag. WATA enables science observations with any of the NIRSpec apertures.
There are 2 locations in quadrant 4 of the micro-shutter assembly that were defined to facilitate MOS observations of extended and moving targets. They are called MSA quadrant 4 ("Q4") field points. The quadrant 4 field points can be used with associated long slit MSA Configurations directly in the observation template. The target specified in the Targets folder will be positioned at the reference point of the associated long slit aperture. If no angle special requirements are placed on the observation, it will be executed with a feasible Aperture Position Angle (Aperture PA) that is assigned to it by STScI.
The Quadrant 4 field points
Two field points, Q4 Field Point 1 and Q4 Field Point 2, were defined for MOS science observations of extended and moving targets. The Q4 Field Point 1 location corresponds to the shutter labeled "q4d250s25" on MSA quadrant 4, while Q4 Field Point 2 is located at "q4d168s73", also in MSA quadrant 4. These labels refer to specific shutters in the MSA Shutter View. The numbers following the 'd' indicate the dispersion direction shutter position, while the numbers following the 's' indicate the spatial shutter location. The 2 field points are positioned to avoid shorted columns and are sufficiently spaced to make it possible to obtain spectra that bridge the wavelengths gap between detectors.
Target acquisition considerations
See Also: TA Recommended Strategies
Using WATA, the offset from the TA position in the wide aperture to the science position at Q4 Field Point 1 will typically be within the visit breaking distance for most orientations. Q4 Field Point 2, by contrast, is much further away and was intended primarily to be used for more extended sources and moving targets with the TA methods Verify-Only or None.
Q4 Field Point 1 is located about 28 arcsec from the S1600A1 wide aperture in which WATA is performed, so it should be straightforward to acquire a compact target using WATA and then move it to the Q4 Field Point 1 for science observations. Q4 Field Point 2 is slightly over 55 arcsec from S1600A1, and so WATA will not be possible unless the APA is restricted and an offset target is selected to reduce the required slew to fall within the visit splitting distance. This field point, Q4 Field Point 2, can be used for extended moving targets where a target acquisition would not be practical. To support the use of the field points with WATA in more scenarios, the minimum visit splitting distance for cycle 1 for WATA was enlarged to 38" in APT.
Science Aperture and long slit MSA Configuration
If WATA, NONE, or Verify_Only are used for target acquisition in the MOS observation APT template, the user can additionally select the Science Aperture (which includes options for the two defined field points). In the example in Figure 1, the Q4 Field Point 1 science aperture has been selected. The user would then choose the corresponding Q4 Field Point 1 long slit for the MSA Configuration in the exposure specification.
Figure 1. MOS Observation Template long slit observation
Click on the figure for a larger view.
Detailed view of the MOS observation template in APT. The Science Aperture selection of one of the Q4 field points is shown, along with the pull-down options for the long slit MSA Configuration for science with the Q4 field point. Normally, the MSA Configuration matching the science aperture should be selected.
Using the long slit configuration in a MOS Observation
See Also: Custom MOS Observations using the MSA Configuration Editor
In APT, navigate to the NIRSpec MultiObject Spectroscopy template, and select any fixed or moving target defined in the proposal Targets folder. In the case of a moving target, the coordinates will of course not be known at the time the observation is defined. The 'TA method' should be set to WATA, NONE, or VERIFY_ONLY. In the Science Parameters area of the observation template, it will then be possible to select the desired field point for the Science Aperture, as shown in Figure 1.
Exposure entries added in the table on the Science Parameters area of the NIRSpec MultiObject Spectroscopy Template include a column for the MSA Configuration. When clicked, the pull-down menu includes the two pre-defined long slit configurations. The pre-defined long slits can be used with the corresponding Q4 field point in the Science Aperture selection. All MSA Configurations, including any that were custom made using the MSA Configuration Editor that reside in the same observation should now be selectable. "ALLOPEN" and "ALLCLOSED" MSA Configurations are also provided.
It is also possible to define long slits at locations other than the Q4 field points using the MSA Configuration Editor. Details on the use of the editor are presented in Custom MOS Observations. In brief, long slits are created with a Option + Left Click (or Alt + Left Click) on a selected column in the MSA Configuration Editor. Any configuration created using the workflow described in this article can be edited by clicking the "Edit Config" button in the Configurations/Pointings table of the observation.
Finally, remember to complete the MOS observation in the MOS APT template to indicate whether confirmation images are also desired.
Figure 2. Quadrant 4 field point locations
A sketch of the locations of the two MSA Quadrant 4 field points labeled 'Field 1' and 'Field 2'. Field 1 corresponds to "Q4 Field Point 1", and Field 2 corresponds to "Q4 Field Point 2". The dispersion direction is from NRS1 toward NRS2, as indicated by the arrow. A representative slit-like MSA Configuration on the Field 2 position is shown. The detector gap is the area between the two green rectangular outlines of the detectors.
References
Proffitt, C. R. et al. 2017, JWST-STScI-005921
The Pre-Flight SI Aperture File, Part 4: NIRSpec