Parallel and No Parallel Special Requirement Rules

This article describes APT rules for using the PARALLEL and the NO PARALLEL ATTACHMENTS special requirements:

  • NO PARALLEL ATTACHMENTS -  Indicates the scheduling software should not attach parallel observations from other programs.
  • PARALLEL (without SLEW ONLY) - Indicates that this observation is a calibration parallel to be matched and attached by the scheduling software to a suitable prime visit.
  • PARALLEL (with SLEW ONLY) - Indicates that this observation is a calibration parallel to be matched attached by VSS the scheduling software to the slew before a suitable prime visit.

For each template these special requirement may be:

  • Implicit - The special requirement is required to be present and may not be removed.
  • Disallowed - The special requirement may not be specified.
  • Allowed - The special requirement may be specified if needed, or omitted otherwise. NO PARALLEL ATTACHMENTS is a Limited Access Parameter, so requires permission for GOs to use.
  • Expected - The special requirement is expected and a warning is generated if it is missing.

Table 1 shows the rules for each template.


Table 1: Rules for PARALLEL and NO PARALLEL ATTACHMENTS special requirements

TemplateSpecial Requirement
(green shading indicates science templates)NO PARALLEL ATTACHMENTSPARALLEL (without Slew Only)PARALLEL [SLEW ONLY]
MIRI


MIRI ImagingAllowed

Disallowed

Disallowed
MIRI LRSAllowed

Disallowed

Disallowed
MIRI MRSAllowed

Disallowed

Disallowed
MIRI Coronagraphic ImagingImplicitDisallowedDisallowed
MIRI DarkAllowedExpectedDisallowed
MIRI External Flat (POINTING TYPE = PRIME)Implicit

Disallowed

Disallowed

MIRI External Flat (POINTING TYPE = PARALLEL)

Disallowed

Disallowed

Implicit
MIRI Anneal

Implicit

Allowed

Expected

MIRI CPCAllowedDisallowedDisallowed
NIRCam


NIRCam ImagingAllowed

Disallowed

Disallowed
NIRCam Coronagraphic Imaging (OBTAIN ASTROMETRIC CONFIRMATION_IMAGES = NO)AllowedDisallowedDisallowed
NIRCam Coronagraphic Imaging (OBTAIN ASTROMETRIC CONFIRMATION_IMAGES = YES)ImplicitDisallowedDisallowed
NIRCam Time SeriesImplicitDisallowedDisallowed
NIRCam Grism Time SeriesImplicitDisallowedDisallowed
NIRCam WFSSAllowedDisallowedDisallowed
NIRCam DarkAllowedExpectedAllowed
NIRCam Wheel ExerciseImplicitDisallowedDisallowed
NIRCam FocusImplicitDisallowedDisallowed
NIRCam IPR ImagingImplicitDisallowedDisallowed
NIRCam PIL ImagingImplicitDisallowedDisallowed
NIRCam External Flat (POINTING TYPE = PRIME)Allowed

Disallowed

Disallowed

NIRCam External Flat (POINTING TYPE = PARALLEL)Allowed

Expected

Allowed
NIRCam Engineering ImagingAllowedAllowedAllowed
NIRISS


NIRISS ImagingAllowed

Disallowed

Disallowed
NIRISS WFSSAllowed

Disallowed

Disallowed
NIRISS SOSSImplicit

Disallowed

Disallowed
NIRISS AMI

Implicit

Disallowed

Disallowed
NIRISS DarkAllowed

Expected 

Disallowed
NIRISS FocusImplicitDisallowedDisallowed
NIRISS Internal Flat (POINTING TYPE = PRIME)Implicit

Disallowed

Disallowed

NIRISS Internal Flat (POINTING TYPE = PARALLEL)

Disallowed

Disallowed

Implicit
NIRISS External Cal (POINTING TYPE = PRIME)Allowed

Disallowed

Disallowed

NIRISS External Cal (POINTING TYPE = PARALLEL)Allowed

Allowed

Expected

NIRSpec


NIRSpec FSSAllowed

Disallowed

Disallowed
NIRSpec IFUAllowed

Disallowed

Disallowed
NIRSpec MOSAllowed

Disallowed

Disallowed
NIRSpec BOTSImplicit 

Disallowed

Disallowed
NIRSpec DarkAllowed ExpectedDisallowed
NIRSpec FocusImplicitDisallowedDisallowed
NIRSpec Focus ReferenceImplicitDisallowedDisallowed
NIRSpec ImagingAllowed

Allowed

(but only when Target=NONE)

Disallowed
NIRSpec Internal Lamp (except when LAMP=NONE or for "Grating Only" mode for all exposures)Implicit

Disallowed

Allowed

NIRSpec Internal Lamp (if LAMP=NONE or with "Grating Only" mode for all exposures)ImplicitAllowedAllowed
NIRSpec MSA Anneal

Implicit 

Disallowed Disallowed
NIRSpec MSA Short DetectImplicitDisallowedDisallowed
NIRSpec MSA MaskingImplicitDisallowedDisallowed
NIRSpec MIMF ImagingAllowed

Disallowed

Disallowed
Fine Guidance (FGS)


FGS External Calibration (POINTING TYPE = PRIME)Allowed

Disallowed

Disallowed

FGS External Calibration (POINTING TYPE = PARALLEL)

Disallowed

ImplicitDisallowed
FGS Internal FlatImplicitDisallowedDisallowed
FGS FocusImplicitDisallowedDisallowed
Wavefront (WFSC)


WFSC CommissioningImplicitDisallowedDisallowed
WFSC Global AlignmentImplicitDisallowed Disallowed
WFSC NIRCam Coarse PhasingImplicitDisallowed Disallowed
WFSC NIRCam Fine PhasingImplicitDisallowedDisallowed
WFSC Commissioning Control OnlyAllowedDisallowed
Disallowed
Spacecraft (SC)


SC Realtime CommandingImplicitDisallowed Disallowed
SC Station KeepingImplicitDisallowedDisallowed
SC Safe Mode Recovery

Implicit

Disallowed

Disallowed
SC Pointing OnlyImplicitDisallowed Disallowed
SC ISIM Dictionary File UpdateImplicitDisallowedDisallowed
SC ISIM ASIC TuningImplicitDisallowedDisallowed


Change log

 

  1. PROPINSTJWST-91634 Updated IRCam Coron Imaging (SUBARRAY = FULL) row from Expected to Allowed.


 

  1. PROPINSTJWST-91632 Added row for NIRCam Coron Imaging (SUBARRAY ≠ FULL).


 

  1. PROPINSTJWST-91597 In Table 1 for NIRCam Corongraphic Imaging, changed Implicit to Expected.


 

  1. PROPINSTJWST-91596 Changed NIRCam Coronographic Imaging to Implict NO PARALLEL ATTACHMENTS.
  2. PROPINSTJWST-91594 Removed cycle dependency for MIRI Anneal in Table 1.


January 3, 2023

  1. Removed "/" from page title. 


November 19, 2022

  1. PROPINSTJWST-91525 Initial version of this article.
  2. PROPINSTJWST-91499 Updated MIRI Anneal section with cycle-dependent requirements.