Time-series observations can be taken with all 4 of JWST's instruments using specific imaging and spectroscopic modes.


Introduction

JWST has four instruments on board, three covering the near-infrared part of the spectrum, and one for the mid-infrared regime. Each instrument has at least one TSO-specific mode of observation, offering the user a range of capabilities for such observations. This article describes the basic parameters for these dedicated TSO modes.

As a reminder, the following conditions are enabled for a "TSO": 

  • dithering is disabled

  • target acquisition is enabled (mandatory for some modes)

  • exposures can take longer than 10,000 seconds

  • high-gain antenna moves are allowed during the exposure

  • data are processed via a dedicated, more minimal, pipeline branch (CALTSO3)

A schematic overview of the available modes is shown in Figure 1.

Figure 1. Overview of JWST capabilities for time-series observations (TSOs)

Overview of TSO modes in JWST. This figure does not yet include TSO imaging with MIRI. (Image: N. Batalha)


Modes overview: TSO imaging

Main articles: NIRCam Time-Series Imaging, MIRI Imaging
See also: MIRI Imaging TSOs

For time-series imaging, the only dedicated, fully-supported mode is in NIRCam, which offers simultaneous imaging in the short and long wavelength channels with a range of broad-, medium- and narrowband filters in each channel. In the short wavelength channel, the user can, in addition, select the weak lens WLP8 to increase the dynamic range. Four different array readout configurations are allowed with all of NIRCam's detector read modes. Time-series imaging is also possible with MIRI, though not with full support for all capabilities. Full details on MIRI TSO imaging capabilities and limitations can be found in the MIRI-Specific TSO Strategies article, in this section, and the MIRI TSO Imaging article in the MIRI documentation.

Links are provided below to further documentation articles on these modes and capabilities.


Table 1. TSO imaging is available in NIRCam; limited support for MIRI TSO imaging

InstrumentMode

Wavelength range (µm)

Filter optionsSubarray optionsRead mode options
NIRCamtime-series imaging

short: 0.6–2.3

long: 2.4–5.0 

(simultaneous)

short: any filter, with/without weak lens WLP8

long: any filter


FULL

SUB400P

SUB160P

SUB64P

RAPID

BRIGHT1

BRIGHT2

SHALLOW2

SHALLOW4

MEDIUM2

MEDIUM8

DEEP2

DEEP8

MIRI (limited)time-series imaging5.625.5all standard imaging filters available (9)

SUB64

FULL

BRIGHTSKY

SUB128

SUB256

FAST



Modes overview: TSO spectroscopy

Main articles: NIRCam Grism Time Series, NIRISS Single Object Slitless Spectroscopy, NIRSpec Bright Object Time Series Observations, MIRI Low-Resolution Spectroscopy
See also: MIRI LRS TSOs

For time-series spectroscopy, the near-IR instruments offer three different types of spectroscopic observations. These modes are optimized for stability over long observations, throughput, and dynamic range. In the mid-IR, MIRI provides low-resolution slitless spectroscopy to 12 µm. The table below gives an overview of the available modes.


Table 2. TSO spectroscopy modes

InstrumentModeWavelength range (µm)Disperser/Filter optionsSpectral resolving powerSubarray optionsRead mode options
NIRCamGrism time-series spectroscopy2.4–5.0short:
  • WLP8 + F182M
  • WLP8 + F187N
  • WLP8 + F210M
  • WLP8 + F212N
  • WLP4+CLEAR*

long:

GrismR plus a wide filter:

  • F277W
  • F322W2
  • F356W
  • F444W
1500

FULL

2048 columns by 64, 128,

or 256 pixel rows

Read out through 4 outputs simulatenously

or via a single output

NIRISS

Single object slitless spectroscopy (SOSS)

0.62.8CLEAR, GR700XD700

SUBSTRIP256 (256 × 2048)

SUBSTRIP96 (96 × 2048)

NISRAPID

NIRSpec


Bright object time-series spectroscopy (BOTS)

  1. 0.7–1.27
  2. 0.97–1.89
  3. 1.66–3.17
  4. 2.87–5.27
  5. 0.7–1.27
  6. 0.97–1.89
  7. 1.66–3.17
  8. 2.87–5.27
  9. 0.6–5.3
  1. G140M/F070LP
  2. G140M/F100LP
  3. G235M/F170LP
  4. G395M/F290LP
  5. G140H/F070LP
  6. G140H/F100LP
  7. G235H/F170LP
  8. G395H/F290LP
  9. PRISM/CLEAR


combinations 14: 1000

combinations 58: 2700

combination 9: 100

SUB2048

SUB1024A

SUB1024B

SUB512

SUB512S

NRSRAPID

NRS

MIRISlitless low-resolution spectroscopy (LRS)512double prism (P750L)100SLITLESSPRISMFAST










Last updated

Published October 04, 2017


 

The format for 'Last updated' is shown below. Enter updates above this internal"Comment" box. Only enter major updates (not typos or formatting changes).


Updated April 5, 2017

  • Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aliquam fermentum vestibulum est. Cras rhoncus. 
  • Pellentesque habitant morbi tristique senectus et netus et malesuada fames ac turpis egestas. Sed quis tortor. 

Published March 2, 2017