The NIRSpec standard target acquisition (MSATA) process uses reference stars to center targets within the MSA, IFU or FS apertures for science observations.  In cases where few reference stars are available, it is possible to use other compact sources with relaxed stellarity.


Content Block
overflowauto
nameContent
id277805920
classpdf-full

Introduction

Parent articleNIRSpec Target Acquisition
See Also: NIRSpec Target Acquisition Recommended Strategies

The NIRSpec standard target acquisition (TA) method MSATA1 will be used for most NIRSpec science observations performed with the micro-shutter assembly (MSA) in the MOS observing mode, and is optionally available for the NIRSpec fixed slits (FS) and IFU observing modes.

During the MSATA procedure, a set of TA reference objects (typically stars) are observed through the open micro-shutters. Their centroids are calculated and used to accurately correct the initial spacecraft pointing and orientation. The achievable TA performance depends significantly on the relative astrometric knowledge of both the reference stars and the science source positions used to plan the TA and the science. The MSATA  procedure is designed to work best when the relative astrometric accuracy of the target field is in the range of 5 to 50 mas. The optimal TA accuracy of about 20 mas requires a relative astrometric accuracy of 5 mas in the planning catalog. 

MSATA is not available for the bright object time-series (BOTS) observing mode because (1) the wide aperture TA available for this template in the JWST Astronomers Proposal Tool (APT) is equally accurate for a single target and takes less time to execute and (2) the required full frame detector readout would likely saturate on any BOTS science sources.

1  Bold italics font style indicates parameters, parameter values, and special requirements that are set in the APT GUI.


Operational sequence of MSATA

The MSATA procedure uses a set of reference stars distributed over the MSA quadrants, determines their observed centroids on the detector, and compares them to the expected positions to calculate a small-angle maneuver that adjusts the initial pointing and position angle. The process acquires two exposures to centroid reference stars in order to accurately align the science targets of interest within their apertures. The centroids of 5–20 reference stars will be measured in a full frame imaging exposure obtained through the "all open" MSA quadrants (or a protected configuration to block bright stars) using both detectors NRS1 and NRS2.  

The available filters for these acquisition images are F110W, F140X, or CLEAR. NIRSpec TA images are always acquired in full frame readout with Ngroups = 3 and detector readout pattern options of  NRS, NRSRAPIDNRSRAPIDD1 and NRSRAPIDD2.  The latter two are available for MSATA only.

The exposure will be repeated at a second dither position which is offset by one-half of an MSA shutter "pitch" (the distance between adjacent shutter centers) in both coordinates. This “half MSA facet slew” is necessary to properly derive the location of the reference stars, minimizing the effect of the physical bars between micro-shutters that could otherwise bias the measured positions of the stars. The description of the micro-shutter assembly presents additional information on the MSA structure. The NIRSpec observation planning tool software will preferentially choose reference stars that are not affected by failed closed micro-shutters.

Both NIRSpec MSATA images are processed by the onboard software to determine precise locations of the reference stars.  These locations are initially measured in pixel coordinates and must be transformed by the software into the distortion-free tangential coordinate system on the sky before they can be compared to the desired sky positions. This coordinate transformation requires precise knowledge of the combined distortion effects of the telescope (Optical Telescope Element; OTE) and NIRSpec, as well as the measured tilt of the NIRSpec target acquisition imaging mirror. The measured centroids of the reference stars will be transformed to sky coordinates and compared with catalog positions expressed in the same sky frame to determine offsets for each reference star and a combined mean pointing offset including a possible roll adjustment.  

 These quantities are calculated using a least squares methodology. After a sigma-clipping and threshold outlier rejection procedure to determine the mean offset and residuals, the telescope will be offset by the final derived mean slew value. The procedure may be repeated once if the overall offset exceeds a specified threshold (1.1") to improve centering accuracy.  Subsequently, a reference image of the centered target field is automatically obtained to conclude the MSATA operational process. The overall timing to execute MSATA is estimated to be 1,440 s per science visit in observation planning. This will be revised as new information becomes available.

Figure container
Figure title

Figure 1. Graphical description of NIRSpec MSATA

Figure caption

Schematic view of the MSA layout, with target acquisition reference stars shown in red, and science targets (blue) shown in their open MSA shutters (green).  Some science targets are not observed because they lie in the same row as other sources (spectral overlap) or because their flux is attenuated by the MSA support grid.  The target acquisition process acquires exposures and carefully measures the reference stars to correct the pointing to the best science position.


Anchor
MSATAacc
MSATAacc
Expected Accuracy of MSATA

Figure 2 shows the NIRSpec target acquisition planning uncertainty as a function of input catalog astrometric accuracy, derived and updated from the estimated error budget definition. 

If  target acquisition uses 5 or more reference stars, the estimated NIRSpec acquisition accuracy will be better than ~20 mas (<1/10 shutter width) if the input planning catalog astrometric accuracy is 5–10 mas. The estimated delivered TA accuracies of better than 25 mas (called optimal TA) are achieved only if planning catalog astrometry is better than about 15 mas for all reference stars and science sources. Delivered estimated TA accuracy of 25–50 mas is possible to achieve using input relative astrometry with 15–40 mas accuracy. 

An estimated TA accuracy level of 50 mas is 1/4 of an MSA shutter width (or 0.2" FS width), and this would result in very significant flux calibration (i.e., slit loss) uncertainty and probable degradation in wavelength calibration accuracy.  Hence, this TA regime (called NIRSpec “relaxed accuracy TA”) should primarily be used for MSA science on very extended sources and use cases that can tolerate a reduced flux calibration accuracy.  A TA accuracy beyond 50 mas is recommended primarily for IFU mode observations. 

Table 1 describes these MSATA accuracy classifications based on input astrometric accuracies for reference stars and science targets.  The Astronomer's Proposal Tool (APT) planning interface with the MSA Planning Tool requests an astrometric catalog accuracy, and these MSATA classifications are presented to users when target acquisition is defined in visits.

Figure container
Figure title

Figure 2. Expected accuracy of the NIRSpec MSATA process as a function of planning catalog accuracy

Figure caption

Expected NIRSpec target acquisition accuracy as a function of input planning catalog (relative) astrometric accuracy. The multiple curves show the expected accuracy for the number of reference stars used in MSATA, from 5 to 20.


Table 1. Description of the "optimal," "relaxed accuracy," and "IFU only" categories used to describe the accuracies achieved in MSATA

Accuracy classification

Input catalog astrometric accuracy (mas)

Estimated TA accuracy (mas)

Optimal

<15

<25

Relaxed accuracy

15–35

25–50

IFU only

>35

50–60



Anchor
MSATABrightnessLimits
MSATABrightnessLimits
Approximate brightness limits for MSATA

The brightness limits for the reference stars in MSATA observations are defined by the instrument filter used to acquire the images, and the detector readout pattern used for the exposures (IRS2 readout patterns are not used for TA). All NIRSpec TA exposures are acquired with Ngroups = 3 (specified using the Acq Groups/Int parameter in APT), which also defines the achieved brightness range.  Table 2 provides the approximate limiting AB magnitudes of sources that might be used for MSATA, and the corresponding instrument settings.  Values are provided for a source with a S/N equal to 20 and for a source near saturation, and for all available TA filters.  These are estimated values based on ground test results and are subject to change.

In addition to the NRSRAPID and NRS readout patterns described in the NIRSpec detector readout patterns pages, MSATA has two additional detector patterns available called NRSRAPIDD1 and NRSRAPIDD2.  These two patterns were added to more efficiently observe the magnitude range achievable for NIRSpec in the MSATA images, particularly for TA in extragalactic deep fields.  The NRSRAPIDD1 and NRSRAPIDD2 patterns are available only with the CLEAR filter.


Table 2. Brightness ranges for NIRSpec MSATA filter and readout pattern options

Readout modeS/N = 20Saturation

F110WF140XCLEARF110WF140XCLEAR
NRSRAPID22.023.023.819.520.621.3
NRSRAPIDD1

24.5

21.9
NRSRAPIDD2

24.9

22.2
NRS24.125.125.721.022.122.8


Limiting bright and faint magnitudes for target acquisition reference stars.  All values are given in AB magnitudes; subtract 0.7 for approximate J-band magnitude values (Vega magnitudes).  Readout Patterns NRSRAPIDD1 and NRSRAPIDD2 are only used with the CLEAR filter for TA exposures. All TA exposures are acquired with Ngroups = 3. 


Observation Planning for MSATA 

In the MOS, IFU and FS science templates, MSATA is an option for target acquisition.  MSATA is expected to be the common target acquisition method for the NIRSpec MOS science mode.  In all cases, the NIRSpec science observations will be defined in a standard way via the Astronomer's Proposal Tool (APT).  The MSATA parameters are defined using a planning catalog with reference stars, ingested in the MSA Planning Tool (MPT)

Warning

NIRSpec MSATA parameters, including reference stars and exposure specifications, cannot be defined at proposal submission. This is because the final execution orient of the observation will likely not be known for proposals. Hence, science observations with the NIRSpec MSA, FSs or the IFU that include target acquisition using the MSATA methodology must be oriented observations (i.e., must have a special requirement that limits the telescope orientation to within 30° of some selected nominal value).

NIRSpec MSATA parameters, including reference stars and exposure specifications, can only be planned after fixed orients are assigned to a NIRSpec MOS program, or for FS or IFU programs using the MSATA method. Execution orients are assigned by the JWST long range plan (LRP) and communicated to teams after proposals are accepted by the JWST time allocation committee.

The observation planning parameters for the NIRSpec standard target acquisition that uses the MSA are defined for each visit that uses the MSATA method.  In order to properly define NIRSpec MSATA observations, the catalog used to plan MOS science observation must have the reference stars included.  IFU or FS science observations that use MSATA must have an available catalog of reference stars in the wider NIRSpec field sampled by the MSA.  In all cases, the catalog must have columns for brightnesses in the NIRSpec target acquisition filters for each potential reference star.  After the science observation is planned, the observer must initiate an automatic search in APT to find reference stars that are available in active MSA regions at the first science pointing of each visit.  APT will present a list of potential target acquisition reference stars that are grouped based on brightness bins defined by the instrument filter and readout pattern (see Table 2).

Tip

For science programs that seek to use this MSA-based target acquisition process for any NIRSpec observing mode, the proposals should either be submitted with an ON HOLD Special Requirement in APT that says "On Hold for Orient Assignment", or have a prescribed aperture position angle special requirement attached to the observations.




Content Block
overflowauto
nameReferences
id281944791
classpdf-hide

References

JWST technical documents

Restrict Content
groupsconfluence-authors


Panel

Block has been set to pdf-hide. Contact Shireen if you enter references




Content Block
overflowauto
nameIcon
id278719485
classpdf-hide

Multiexcerpt include
MultiExcerptNameNIRSpec icon and Name
PageWithExcerptMR:NIRSpec icon and name


Content Block
nameUpdates
id1074221578
classpdf-hide


HTML Wrap
padding0
margin0
idupdatesbox


HTML Wrap
tagspan
classupdatesbox-heading

Last updated

Published July 29, 2017


 

Comment

The format for 'Last updated' is shown below. Enter updates above this internal"Comment" box. Only enter major updates (not typos or formatting changes).


Updated April 05, 2017

  • Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aliquam fermentum vestibulum est. Cras rhoncus. 
  • Pellentesque habitant morbi tristique senectus et netus et malesuada fames ac turpis egestas. Sed quis tortor. 

Published March 02, 2017