MIRI Imaging TSOs

JWST MIRI currently has limited support for time-series observations (TSOs) with the imager.

On this page

The MIRI imager has limited support for high precision imaging photometry in time-series observations (TSOs). Available capabilities and limitations for such observations are described below.



Sensitivity and saturation

See also: MIRI SensitivityMIRI Bright Source Limits

Sensitivities and saturation limits are available in the description of MIRI Predicted Performance.

Users should always refer to the Exposure Time Calculator Old for the most accurate signal-to-noise calculations.



Dithering

See also: MIRI Imaging Dithering

Contrary to regular imaging observations, TSOs should be carried out without dithering to maintain target position on the same pixels throughout the observation.

Imaging observations with Dither 1 set to None are currently available as a standard option only for the SUB64 subarray. Non-dithered imaging for the FULL array and other subarrays are a limited access option in APT that can only be selected by checking the Allow Restricted box in the Proposal Information form. Note that use of limited access options requires justification in the proposal text.

    Page not found for multiexcerpt macro.
The page: APT GUI footnote was not found. Please check/update the page name used in the 'multiexcerpt-include macro.



Filters and subarrays

See also: MIRI Filters and DispersersMIRI Detector Subarrays

All filters available for general MIRI imaging observations can be selected for TSOs.



Target acquisition

See also: MIRI Imaging Target Acquisition

Target acquisition with the MIRI imager, whilst recommended for TSOs, is not currently supported. It is expected to become available in the future.



Exposure time limitations

See also: JWST Exposure Time Calculator Overview

Regular (non-TSO) MIRI imager observations have an exposure time limit of 10,000 s for a single exposure. For TSOs, this limitation can be waived to allow observations of long time-variable phenomena in a single exposure, which is optimal for stability and photometric precision. Selecting Time Series Observation in the Special Requirements pane in APT enables this waiver. 



Imaging TSOs in APT

See also: MIRI Imaging TSOs

MIRI imaging observing proposals for TSOs should use the standard MIRI imaging template, then select the Time Series Observation and No Parallel special requirements to enable the optimal TSO functionality. This will waive the exposure time limit.

Support for imaging TSOs with MIRI in APT is currently still under development.




Published

 

Latest updates